forked from simonjj/SnmpMibs
-
Notifications
You must be signed in to change notification settings - Fork 0
/
EtherLike-MIB.mib
1862 lines (1591 loc) · 82.5 KB
/
EtherLike-MIB.mib
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
949
950
951
952
953
954
955
956
957
958
959
960
961
962
963
964
965
966
967
968
969
970
971
972
973
974
975
976
977
978
979
980
981
982
983
984
985
986
987
988
989
990
991
992
993
994
995
996
997
998
999
1000
EtherLike-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY, OBJECT-TYPE, OBJECT-IDENTITY,
Integer32, Counter32, Counter64, mib-2, transmission
FROM SNMPv2-SMI
MODULE-COMPLIANCE, OBJECT-GROUP
FROM SNMPv2-CONF
TruthValue
FROM SNMPv2-TC
ifIndex, InterfaceIndex
FROM IF-MIB;
etherMIB MODULE-IDENTITY
LAST-UPDATED "200309190000Z" -- September 19, 2003
ORGANIZATION "IETF Ethernet Interfaces and Hub MIB
Working Group"
CONTACT-INFO
"WG E-mail: [email protected]
To subscribe: [email protected]
Chair: Dan Romascanu
Postal: Avaya Inc.
Atidum Technology Park, Bldg. 3
Tel Aviv 61131
Israel
Tel: +972 3 645 8414
E-mail: [email protected]
Editor: John Flick
Postal: Hewlett-Packard Company
8000 Foothills Blvd. M/S 5557
Roseville, CA 95747-5557
USA
Tel: +1 916 785 4018
Fax: +1 916 785 1199
E-mail: [email protected]"
DESCRIPTION "The MIB module to describe generic objects for
ethernet-like network interfaces.
The following reference is used throughout this
MIB module:
[IEEE 802.3 Std] refers to:
IEEE Std 802.3, 2002 Edition: 'IEEE Standard
for Information technology -
Telecommunications and information exchange
between systems - Local and metropolitan
area networks - Specific requirements -
Part 3: Carrier sense multiple access with
collision detection (CSMA/CD) access method
and physical layer specifications', as
amended by IEEE Std 802.3ae-2002:
'Amendment: Media Access Control (MAC)
Parameters, Physical Layer, and Management
Parameters for 10 Gb/s Operation', August,
2002.
Of particular interest is Clause 30, '10 Mb/s,
100 Mb/s, 1000 Mb/s, and 10 Gb/s Management'.
Copyright (C) The Internet Society (2003). This
version of this MIB module is part of RFC 3635;
see the RFC itself for full legal notices."
REVISION "200309190000Z" -- September 19, 2003
DESCRIPTION "Updated to include support for 10 Gb/sec
interfaces. This resulted in the following
revisions:
- Updated dot3StatsAlignmentErrors and
dot3StatsSymbolErrors DESCRIPTIONs to
reflect behaviour at 10 Gb/s
- Added dot3StatsRateControlAbility and
dot3RateControlStatus for management
of the Rate Control function in 10 Gb/s
WAN applications
- Added 64-bit versions of all counters
that are used on high-speed ethernet
interfaces
- Added object groups to contain the new
objects
- Deprecated etherStatsBaseGroup and
split into etherStatsBaseGroup2 and
etherStatsHalfDuplexGroup, so that
interfaces which can only operate at
full-duplex do not need to implement
half-duplex-only statistics
- Deprecated dot3Compliance and replaced
it with dot3Compliance2, which includes
the compliance information for the new
object groups
In addition, the dot3Tests and dot3Errors
object identities have been deprecated,
since there is no longer a standard method
for using them.
This version published as RFC 3635."
REVISION "199908240400Z" -- August 24, 1999
DESCRIPTION "Updated to include support for 1000 Mb/sec
interfaces and full-duplex interfaces.
This version published as RFC 2665."
REVISION "199806032150Z" -- June 3, 1998
DESCRIPTION "Updated to include support for 100 Mb/sec
interfaces.
This version published as RFC 2358."
REVISION "199402030400Z" -- February 3, 1994
DESCRIPTION "Initial version, published as RFC 1650."
::= { mib-2 35 }
etherMIBObjects OBJECT IDENTIFIER ::= { etherMIB 1 }
dot3 OBJECT IDENTIFIER ::= { transmission 7 }
-- the Ethernet-like Statistics group
dot3StatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot3StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Statistics for a collection of ethernet-like
interfaces attached to a particular system.
There will be one row in this table for each
ethernet-like interface in the system."
::= { dot3 2 }
dot3StatsEntry OBJECT-TYPE
SYNTAX Dot3StatsEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "Statistics for a particular interface to an
ethernet-like medium."
INDEX { dot3StatsIndex }
::= { dot3StatsTable 1 }
Dot3StatsEntry ::=
SEQUENCE {
dot3StatsIndex InterfaceIndex,
dot3StatsAlignmentErrors Counter32,
dot3StatsFCSErrors Counter32,
dot3StatsSingleCollisionFrames Counter32,
dot3StatsMultipleCollisionFrames Counter32,
dot3StatsSQETestErrors Counter32,
dot3StatsDeferredTransmissions Counter32,
dot3StatsLateCollisions Counter32,
dot3StatsExcessiveCollisions Counter32,
dot3StatsInternalMacTransmitErrors Counter32,
dot3StatsCarrierSenseErrors Counter32,
dot3StatsFrameTooLongs Counter32,
dot3StatsInternalMacReceiveErrors Counter32,
dot3StatsEtherChipSet OBJECT IDENTIFIER,
dot3StatsSymbolErrors Counter32,
dot3StatsDuplexStatus INTEGER,
dot3StatsRateControlAbility TruthValue,
dot3StatsRateControlStatus INTEGER
}
dot3StatsIndex OBJECT-TYPE
SYNTAX InterfaceIndex
MAX-ACCESS read-only -- read-only since originally an
-- SMIv1 index
STATUS current
DESCRIPTION "An index value that uniquely identifies an
interface to an ethernet-like medium. The
interface identified by a particular value of
this index is the same interface as identified
by the same value of ifIndex."
REFERENCE "RFC 2863, ifIndex"
::= { dot3StatsEntry 1 }
dot3StatsAlignmentErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames received on a particular
interface that are not an integral number of
octets in length and do not pass the FCS check.
The count represented by an instance of this
object is incremented when the alignmentError
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions pertain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC.
This counter does not increment for group
encoding schemes greater than 4 bits per group.
For interfaces operating at 10 Gb/s, this
counter can roll over in less than 5 minutes if
it is incrementing at its maximum rate. Since
that amount of time could be less than a
management station's poll cycle time, in order
to avoid a loss of information, a management
station is advised to poll the
dot3HCStatsAlignmentErrors object for 10 Gb/s
or faster interfaces.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.7,
aAlignmentErrors"
::= { dot3StatsEntry 2 }
dot3StatsFCSErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames received on a particular
interface that are an integral number of octets
in length but do not pass the FCS check. This
count does not include frames received with
frame-too-long or frame-too-short error.
The count represented by an instance of this
object is incremented when the frameCheckError
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions pertain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC.
Note: Coding errors detected by the physical
layer for speeds above 10 Mb/s will cause the
frame to fail the FCS check.
For interfaces operating at 10 Gb/s, this
counter can roll over in less than 5 minutes if
it is incrementing at its maximum rate. Since
that amount of time could be less than a
management station's poll cycle time, in order
to avoid a loss of information, a management
station is advised to poll the
dot3HCStatsFCSErrors object for 10 Gb/s or
faster interfaces.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.6,
aFrameCheckSequenceErrors."
::= { dot3StatsEntry 3 }
dot3StatsSingleCollisionFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames that are involved in a single
collision, and are subsequently transmitted
successfully.
A frame that is counted by an instance of this
object is also counted by the corresponding
instance of either the ifOutUcastPkts,
ifOutMulticastPkts, or ifOutBroadcastPkts,
and is not counted by the corresponding
instance of the dot3StatsMultipleCollisionFrames
object.
This counter does not increment when the
interface is operating in full-duplex mode.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.3,
aSingleCollisionFrames."
::= { dot3StatsEntry 4 }
dot3StatsMultipleCollisionFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames that are involved in more
than one collision and are subsequently
transmitted successfully.
A frame that is counted by an instance of this
object is also counted by the corresponding
instance of either the ifOutUcastPkts,
ifOutMulticastPkts, or ifOutBroadcastPkts,
and is not counted by the corresponding
instance of the dot3StatsSingleCollisionFrames
object.
This counter does not increment when the
interface is operating in full-duplex mode.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.4,
aMultipleCollisionFrames."
::= { dot3StatsEntry 5 }
dot3StatsSQETestErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of times that the SQE TEST ERROR
is received on a particular interface. The
SQE TEST ERROR is set in accordance with the
rules for verification of the SQE detection
mechanism in the PLS Carrier Sense Function as
described in IEEE Std. 802.3, 2000 Edition,
section 7.2.4.6.
This counter does not increment on interfaces
operating at speeds greater than 10 Mb/s, or on
interfaces operating in full-duplex mode.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 7.2.4.6, also 30.3.2.1.4,
aSQETestErrors."
::= { dot3StatsEntry 6 }
dot3StatsDeferredTransmissions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames for which the first
transmission attempt on a particular interface
is delayed because the medium is busy.
The count represented by an instance of this
object does not include frames involved in
collisions.
This counter does not increment when the
interface is operating in full-duplex mode.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.9,
aFramesWithDeferredXmissions."
::= { dot3StatsEntry 7 }
dot3StatsLateCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of times that a collision is
detected on a particular interface later than
one slotTime into the transmission of a packet.
A (late) collision included in a count
represented by an instance of this object is
also considered as a (generic) collision for
purposes of other collision-related
statistics.
This counter does not increment when the
interface is operating in full-duplex mode.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.10,
aLateCollisions."
::= { dot3StatsEntry 8 }
dot3StatsExcessiveCollisions OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames for which transmission on a
particular interface fails due to excessive
collisions.
This counter does not increment when the
interface is operating in full-duplex mode.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.11,
aFramesAbortedDueToXSColls."
::= { dot3StatsEntry 9 }
dot3StatsInternalMacTransmitErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames for which transmission on a
particular interface fails due to an internal
MAC sublayer transmit error. A frame is only
counted by an instance of this object if it is
not counted by the corresponding instance of
either the dot3StatsLateCollisions object, the
dot3StatsExcessiveCollisions object, or the
dot3StatsCarrierSenseErrors object.
The precise meaning of the count represented by
an instance of this object is implementation-
specific. In particular, an instance of this
object may represent a count of transmission
errors on a particular interface that are not
otherwise counted.
For interfaces operating at 10 Gb/s, this
counter can roll over in less than 5 minutes if
it is incrementing at its maximum rate. Since
that amount of time could be less than a
management station's poll cycle time, in order
to avoid a loss of information, a management
station is advised to poll the
dot3HCStatsInternalMacTransmitErrors object for
10 Gb/s or faster interfaces.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.12,
aFramesLostDueToIntMACXmitError."
::= { dot3StatsEntry 10 }
dot3StatsCarrierSenseErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The number of times that the carrier sense
condition was lost or never asserted when
attempting to transmit a frame on a particular
interface.
The count represented by an instance of this
object is incremented at most once per
transmission attempt, even if the carrier sense
condition fluctuates during a transmission
attempt.
This counter does not increment when the
interface is operating in full-duplex mode.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.13,
aCarrierSenseErrors."
::= { dot3StatsEntry 11 }
-- { dot3StatsEntry 12 } is not assigned
dot3StatsFrameTooLongs OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames received on a particular
interface that exceed the maximum permitted
frame size.
The count represented by an instance of this
object is incremented when the frameTooLong
status is returned by the MAC service to the
LLC (or other MAC user). Received frames for
which multiple error conditions pertain are,
according to the conventions of IEEE 802.3
Layer Management, counted exclusively according
to the error status presented to the LLC.
For interfaces operating at 10 Gb/s, this
counter can roll over in less than 80 minutes if
it is incrementing at its maximum rate. Since
that amount of time could be less than a
management station's poll cycle time, in order
to avoid a loss of information, a management
station is advised to poll the
dot3HCStatsFrameTooLongs object for 10 Gb/s
or faster interfaces.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.25,
aFrameTooLongErrors."
::= { dot3StatsEntry 13 }
-- { dot3StatsEntry 14 } is not assigned
-- { dot3StatsEntry 15 } is not assigned
dot3StatsInternalMacReceiveErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of frames for which reception on a
particular interface fails due to an internal
MAC sublayer receive error. A frame is only
counted by an instance of this object if it is
not counted by the corresponding instance of
either the dot3StatsFrameTooLongs object, the
dot3StatsAlignmentErrors object, or the
dot3StatsFCSErrors object.
The precise meaning of the count represented by
an instance of this object is implementation-
specific. In particular, an instance of this
object may represent a count of receive errors
on a particular interface that are not
otherwise counted.
For interfaces operating at 10 Gb/s, this
counter can roll over in less than 5 minutes if
it is incrementing at its maximum rate. Since
that amount of time could be less than a
management station's poll cycle time, in order
to avoid a loss of information, a management
station is advised to poll the
dot3HCStatsInternalMacReceiveErrors object for
10 Gb/s or faster interfaces.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.15,
aFramesLostDueToIntMACRcvError."
::= { dot3StatsEntry 16 }
dot3StatsEtherChipSet OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
MAX-ACCESS read-only
STATUS deprecated
DESCRIPTION "******** THIS OBJECT IS DEPRECATED ********
This object contains an OBJECT IDENTIFIER
which identifies the chipset used to
realize the interface. Ethernet-like
interfaces are typically built out of
several different chips. The MIB implementor
is presented with a decision of which chip
to identify via this object. The implementor
should identify the chip which is usually
called the Medium Access Control chip.
If no such chip is easily identifiable,
the implementor should identify the chip
which actually gathers the transmit
and receive statistics and error
indications. This would allow a
manager station to correlate the
statistics and the chip generating
them, giving it the ability to take
into account any known anomalies
in the chip.
This object has been deprecated. Implementation
feedback indicates that it is of limited use for
debugging network problems in the field, and
the administrative overhead involved in
maintaining a registry of chipset OIDs is not
justified."
::= { dot3StatsEntry 17 }
dot3StatsSymbolErrors OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "For an interface operating at 100 Mb/s, the
number of times there was an invalid data symbol
when a valid carrier was present.
For an interface operating in half-duplex mode
at 1000 Mb/s, the number of times the receiving
media is non-idle (a carrier event) for a period
of time equal to or greater than slotTime, and
during which there was at least one occurrence
of an event that causes the PHY to indicate
'Data reception error' or 'carrier extend error'
on the GMII.
For an interface operating in full-duplex mode
at 1000 Mb/s, the number of times the receiving
media is non-idle (a carrier event) for a period
of time equal to or greater than minFrameSize,
and during which there was at least one
occurrence of an event that causes the PHY to
indicate 'Data reception error' on the GMII.
For an interface operating at 10 Gb/s, the
number of times the receiving media is non-idle
(a carrier event) for a period of time equal to
or greater than minFrameSize, and during which
there was at least one occurrence of an event
that causes the PHY to indicate 'Receive Error'
on the XGMII.
The count represented by an instance of this
object is incremented at most once per carrier
event, even if multiple symbol errors occur
during the carrier event. This count does
not increment if a collision is present.
This counter does not increment when the
interface is operating at 10 Mb/s.
For interfaces operating at 10 Gb/s, this
counter can roll over in less than 5 minutes if
it is incrementing at its maximum rate. Since
that amount of time could be less than a
management station's poll cycle time, in order
to avoid a loss of information, a management
station is advised to poll the
dot3HCStatsSymbolErrors object for 10 Gb/s
or faster interfaces.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.2.1.5,
aSymbolErrorDuringCarrier."
::= { dot3StatsEntry 18 }
dot3StatsDuplexStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
halfDuplex(2),
fullDuplex(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current mode of operation of the MAC
entity. 'unknown' indicates that the current
duplex mode could not be determined.
Management control of the duplex mode is
accomplished through the MAU MIB. When
an interface does not support autonegotiation,
or when autonegotiation is not enabled, the
duplex mode is controlled using
ifMauDefaultType. When autonegotiation is
supported and enabled, duplex mode is controlled
using ifMauAutoNegAdvertisedBits. In either
case, the currently operating duplex mode is
reflected both in this object and in ifMauType.
Note that this object provides redundant
information with ifMauType. Normally, redundant
objects are discouraged. However, in this
instance, it allows a management application to
determine the duplex status of an interface
without having to know every possible value of
ifMauType. This was felt to be sufficiently
valuable to justify the redundancy."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.32,
aDuplexStatus."
::= { dot3StatsEntry 19 }
dot3StatsRateControlAbility OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION "'true' for interfaces operating at speeds above
1000 Mb/s that support Rate Control through
lowering the average data rate of the MAC
sublayer, with frame granularity, and 'false'
otherwise."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.33,
aRateControlAbility."
::= { dot3StatsEntry 20 }
dot3StatsRateControlStatus OBJECT-TYPE
SYNTAX INTEGER {
rateControlOff(1),
rateControlOn(2),
unknown(3)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "The current Rate Control mode of operation of
the MAC sublayer of this interface."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.34,
aRateControlStatus."
::= { dot3StatsEntry 21 }
-- the Ethernet-like Collision Statistics group
-- Implementation of this group is optional; it is appropriate
-- for all systems which have the necessary metering
dot3CollTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot3CollEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A collection of collision histograms for a
particular set of interfaces."
REFERENCE "[IEEE 802.3 Std.], 30.3.1.1.30,
aCollisionFrames."
::= { dot3 5 }
dot3CollEntry OBJECT-TYPE
SYNTAX Dot3CollEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A cell in the histogram of per-frame
collisions for a particular interface. An
instance of this object represents the
frequency of individual MAC frames for which
the transmission (successful or otherwise) on a
particular interface is accompanied by a
particular number of media collisions."
INDEX { ifIndex, dot3CollCount }
::= { dot3CollTable 1 }
Dot3CollEntry ::=
SEQUENCE {
dot3CollCount Integer32,
dot3CollFrequencies Counter32
}
-- { dot3CollEntry 1 } is no longer in use
dot3CollCount OBJECT-TYPE
SYNTAX Integer32 (1..16)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "The number of per-frame media collisions for
which a particular collision histogram cell
represents the frequency on a particular
interface."
::= { dot3CollEntry 2 }
dot3CollFrequencies OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of individual MAC frames for which the
transmission (successful or otherwise) on a
particular interface occurs after the
frame has experienced exactly the number
of collisions in the associated
dot3CollCount object.
For example, a frame which is transmitted
on interface 77 after experiencing
exactly 4 collisions would be indicated
by incrementing only dot3CollFrequencies.77.4.
No other instance of dot3CollFrequencies would
be incremented in this example.
This counter does not increment when the
interface is operating in full-duplex mode.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
::= { dot3CollEntry 3 }
dot3ControlTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot3ControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of descriptive and status information
about the MAC Control sublayer on the
ethernet-like interfaces attached to a
particular system. There will be one row in
this table for each ethernet-like interface in
the system which implements the MAC Control
sublayer. If some, but not all, of the
ethernet-like interfaces in the system implement
the MAC Control sublayer, there will be fewer
rows in this table than in the dot3StatsTable."
::= { dot3 9 }
dot3ControlEntry OBJECT-TYPE
SYNTAX Dot3ControlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about the MAC Control sublayer on a single
ethernet-like interface."
INDEX { dot3StatsIndex }
::= { dot3ControlTable 1 }
Dot3ControlEntry ::=
SEQUENCE {
dot3ControlFunctionsSupported BITS,
dot3ControlInUnknownOpcodes Counter32,
dot3HCControlInUnknownOpcodes Counter64
}
dot3ControlFunctionsSupported OBJECT-TYPE
SYNTAX BITS {
pause(0) -- 802.3 flow control
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A list of the possible MAC Control functions
implemented for this interface."
REFERENCE "[IEEE 802.3 Std.], 30.3.3.2,
aMACControlFunctionsSupported."
::= { dot3ControlEntry 1 }
dot3ControlInUnknownOpcodes OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of MAC Control frames received on this
interface that contain an opcode that is not
supported by this device.
For interfaces operating at 10 Gb/s, this
counter can roll over in less than 5 minutes if
it is incrementing at its maximum rate. Since
that amount of time could be less than a
management station's poll cycle time, in order
to avoid a loss of information, a management
station is advised to poll the
dot3HCControlInUnknownOpcodes object for 10 Gb/s
or faster interfaces.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.3.5,
aUnsupportedOpcodesReceived"
::= { dot3ControlEntry 2 }
dot3HCControlInUnknownOpcodes OBJECT-TYPE
SYNTAX Counter64
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of MAC Control frames received on this
interface that contain an opcode that is not
supported by this device.
This counter is a 64 bit version of
dot3ControlInUnknownOpcodes. It should be used
on interfaces operating at 10 Gb/s or faster.
Discontinuities in the value of this counter can
occur at re-initialization of the management
system, and at other times as indicated by the
value of ifCounterDiscontinuityTime."
REFERENCE "[IEEE 802.3 Std.], 30.3.3.5,
aUnsupportedOpcodesReceived"
::= { dot3ControlEntry 3 }
dot3PauseTable OBJECT-TYPE
SYNTAX SEQUENCE OF Dot3PauseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "A table of descriptive and status information
about the MAC Control PAUSE function on the
ethernet-like interfaces attached to a
particular system. There will be one row in
this table for each ethernet-like interface in
the system which supports the MAC Control PAUSE
function (i.e., the 'pause' bit in the
corresponding instance of
dot3ControlFunctionsSupported is set). If some,
but not all, of the ethernet-like interfaces in
the system implement the MAC Control PAUSE
function (for example, if some interfaces only
support half-duplex), there will be fewer rows
in this table than in the dot3StatsTable."
::= { dot3 10 }
dot3PauseEntry OBJECT-TYPE
SYNTAX Dot3PauseEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION "An entry in the table, containing information
about the MAC Control PAUSE function on a single
ethernet-like interface."
INDEX { dot3StatsIndex }
::= { dot3PauseTable 1 }
Dot3PauseEntry ::=
SEQUENCE {
dot3PauseAdminMode INTEGER,
dot3PauseOperMode INTEGER,
dot3InPauseFrames Counter32,
dot3OutPauseFrames Counter32,
dot3HCInPauseFrames Counter64,
dot3HCOutPauseFrames Counter64
}
dot3PauseAdminMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabledXmit(2),
enabledRcv(3),
enabledXmitAndRcv(4)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION "This object is used to configure the default
administrative PAUSE mode for this interface.
This object represents the
administratively-configured PAUSE mode for this
interface. If auto-negotiation is not enabled
or is not implemented for the active MAU
attached to this interface, the value of this
object determines the operational PAUSE mode
of the interface whenever it is operating in
full-duplex mode. In this case, a set to this
object will force the interface into the
specified mode.
If auto-negotiation is implemented and enabled
for the MAU attached to this interface, the
PAUSE mode for this interface is determined by
auto-negotiation, and the value of this object
denotes the mode to which the interface will
automatically revert if/when auto-negotiation is
later disabled. Note that when auto-negotiation
is running, administrative control of the PAUSE
mode may be accomplished using the
ifMauAutoNegCapAdvertisedBits object in the
MAU-MIB.
Note that the value of this object is ignored
when the interface is not operating in
full-duplex mode.
An attempt to set this object to
'enabledXmit(2)' or 'enabledRcv(3)' will fail
on interfaces that do not support operation
at greater than 100 Mb/s."
::= { dot3PauseEntry 1 }
dot3PauseOperMode OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabledXmit(2),
enabledRcv(3),
enabledXmitAndRcv(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION "This object reflects the PAUSE mode currently
in use on this interface, as determined by
either (1) the result of the auto-negotiation
function or (2) if auto-negotiation is not
enabled or is not implemented for the active MAU
attached to this interface, by the value of
dot3PauseAdminMode. Interfaces operating at
100 Mb/s or less will never return
'enabledXmit(2)' or 'enabledRcv(3)'. Interfaces
operating in half-duplex mode will always return
'disabled(1)'. Interfaces on which
auto-negotiation is enabled but not yet
completed should return the value
'disabled(1)'."
::= { dot3PauseEntry 2 }
dot3InPauseFrames OBJECT-TYPE
SYNTAX Counter32
MAX-ACCESS read-only
STATUS current
DESCRIPTION "A count of MAC Control frames received on this
interface with an opcode indicating the PAUSE
operation.
This counter does not increment when the
interface is operating in half-duplex mode.
For interfaces operating at 10 Gb/s, this
counter can roll over in less than 5 minutes if
it is incrementing at its maximum rate. Since
that amount of time could be less than a
management station's poll cycle time, in order